> HOME   > FAQ   > SITEMAP

PIPENET VISION >

PIPENET VISION

PIPENET VISION Software Modules 

" LEADING THE WAY IN FLUID FLOW ANALYSIS "

PIPENET VISION Software Modoule -

                  Transient Module

                  Spray/Sprinkler Module

                  Standard Module

PIPENET Vision 1.6 is now available !NEW

PIPENET VISION 1.50 - Enhancements  

PIPENET at the heart of the Power Industry -Steam Hammer in the Main

            Steam System  

PIPENET VISION eNEWSLETTER - December 2010 
PIPENET VISION Transient modules's new graphing tool-superimposition of

            multiple graphs  NEW

PIPENET VISION Quick Demo - Spray/Sprinkler Module

PIPENET VISION Quick Demo - Standard Module 

PIPENET VISION Quick Demo - Transient Module 

PIPENET VISION News February 2011 NEW

PIPENET VISION 1.41- New Features  

PIPENET VISION 1.41- New Features

PIPENET VISION Brochure

PIPENET VISION 1.40- New Features

PIPENET VISION 1.32- New Features  

PIPENET VISION within Industries

PIPENET VISION Newsletters - Summer 2008_ Issued

PIPENET VISION Newsletters - September 2006

PIPENET VISION Demo on Applications

PIPENET VISION Demo Training

PIPENET VISION Unique Feature & Tips-Demo

Case Studies

PIPENET Spray/Sprinkle Module - NFPA rules NFPA rules

PIPENET Standard Module - Steady Flow of Fluids in Pipes

PIPENET Transient Module - Surge Analysis/Hydraulic Analysis

SOME EXAMPLES OF FIRE PROTECTION SYSTEMS MODELLED IN PIPENET

            SPRAY/SPRINKLER MODULE

SOLVING LIQUID HAMMER PROBLEMS, USING PIPENET VISION and

           CAESAR II   Prepared By: Farhad Salehi

VACUUM BREAKERS IN FIREWATER SYSTEMS

PDMS to PIPENET Interface

Presentation Seminar Form Oil, Gas, Petrochemical & Power Industries

 

PIPENET VISION Process & Power Industry Presentation        

 

Presentation Seminar Form -  POWER INDUSTRY

Simple Example on using PIPENET VISION interface with AutoCAD

Examples of Schematic Drawings Showing the  use of PIPENET VISION

 

PIPENET VISION Transient Module

provides a rapid means of in-house rigorous transient analysis and pinpoints problem areas and potential solutions.

   Click on image to enlarge

Applications of PIPENET VISION Transient module:

  • Loading/unloading systems analysis

  • Cooling water systems modeling

  • Firewater systems surge analysis

  • Water injection systems studies

  • Subsea and cross country pipelines

  • Steam hammer

    Click on image to enlarge

    Click on image to enlarge 

PIPENET Transient is the perfect tool for modeling
networks:

 

  • Pipes – rigorous and short, mile post data

  • Valves – operating, surge relief, control,
    non-return, swing check, regulating, bursting
    disk, inertial check

  • Pumps – simple and turbo

  • Tanks – simple, accumulator, surge, receiving vessel

  • Vacuum breakers – with or without hysteresis

__________________

  • Control systems – pressure, flow, differential pressure sensors, PID control, transfer functions, switches

  • Caissons – partially filled pipes

  • Specifications – extensive range of boundary conditions

  • Hydraulic transient forces – dynamic/total, unbalanced/complex forces
     

Click on image to enlarge

  • PIPENET Transient Features:

    Output – graphical, tabular and forces output, snapshot, dynamic movie, min/max tables, pressure envelopes, hydraulic grade lines

  • Initial state – steady state, user-defined, run-in time, final steady state

  • Cavitation modeling – simple cavitation, cavity separation with elevation effect

  • Time step – fixed/variable, software/user-defined

  • Force – time history neutral file output for reading by pipe stress analysis and finite element programs


    PIPENET Transient professionally performs dynamic analysis with ease and accuracy.

Click on image to enlarge

 

 

 

 

Up5

PIPENET VISION Spray/Sprinkler Module

PIPENET Spray/Sprinkler Module is excellent for
hydraulic analysis of firewater systems in compliance
with NFPA13, NFPA15 and NFPA16 rules. This
addresses the hydraulic analysis requirements of virtually
all national and international standards. Ideal for the
design of systems used in critical applications such as
offshore platforms, FPSO’s, petrochemical plants,
power plants, refineries, ships, and airport hangers.

    Click on image to enlarge

Applications of PIPENET Spray/Sprinkler module:

  • Deluge systems

  • Firewater ringmain systems

  • Sprinkler systems

  • Foam solution systems

  • Foam concentrate systems

  • Spray mist systems

PIPENET Spray/Sprinkler is the ideal modeling tool for:

Pipes, nozzles, fittings, overboard dump valves,
non-return valves, orifice plates, equipment items.

    Click on image to enlarge

PIPENET Spray/Sprinkler Features:

  • Input – isometric or orthogonal schematic input,
    tabular input including copy and paste from
    spreadsheets 

  • Underlay – import of drawings for use as
    underlays for schematic drawings

  • Output – easy, readable output as tables, or
    display of data and results on the schematic

____________

  • Choice of calculation modes – hydraulically mostremote nozzle, inlet pressure/flowrate

  • Orifice plates – diameter to be calculated
    or specified

  • Multiple pump scenarios

  • Multiple fire scenarios

  • Block/Break of pipes to simulate closed valves
    and burst pipes

  • Pumps – sizing of pumps or user-defined vendor’s pump curves
     

Click on image to enlarge

  • Pipe schedules – built-in and user-defined pipe schedules, lined pipes, multiple pipe schedules in one system

  • Overboard dump and minimum flow valves

  • User defined libraries of pipe schedules, nozzles,
    deluge valves and linings

     

Click on image to enlarge

  • Choice of Hazen-Williams and Darcy-Weisbach equations

  • Choice of pipe or node elevations

 

PIPENET Spray/Sprinkler module is the fire protection professional’s first choice.

Up5

PIPENET Standard Module

PIPENET Standard Module is ideal for analysis of
general network systems handling liquids, gases and
steam, including piping HVAC and ducting systems.
Applications of PIPENET Standard Module:

  • Cooling water systems

  • Steam distribution systems

  • Ventilation systems

  • Water distribution systems

  • Fuel gas systems

  • Chilled water systems

  • Ventilation systems

PIPENET Standard Models:

Pipes, ducts, fittings, pumps, fans, check valves, control valves, nozzles, filters, orifice plates, fixed pressure drops.

   Click on image to enlarge

PIPENET Standard Features:

  • Input – isometric or orthogonal schematic input, tabular input including copy and paste from spreadsheets 

  • Underlay – import of drawings for use as underlays for schematic drawings

  • Output – easy, readable output as tables, or display of data and results on the schematic

  • Extensive library of fittings and user-defined fittings, using Crane data

  • Powerful pipe sizing capability

  • Orifice plates – diameter to be calculated or specified

  • Multiple pump scenarios

  • Block/Break of pipes to simulate closed valves and burst pipes

  • Pumps – sizing of pumps or user-defined vendor’s pump curves

  • Pipe schedules – extensive built-in and userdefined pipe schedules

  • Checking for cavitation, correction for ambient pressure decrease with height, calculation of hydraulic gradients and modeling of leaks

Click on image to enlarge

  • Control valves – pressure, flow, differential and set positione

  • Variable properties and temperatures

  • Choice of pipe or node elevations



PIPENET is the solution in design optimisation and
setting standards in safety.

Click on image to enlarge

     Click on image to enlarge

 

Up5

 