PIPENET VISION Transient Module
provides a rapid means of in-house rigorous transient analysis and
pinpoints problem areas and
potential solutions.
Click on
image to enlarge
Applications of
PIPENET
VISION
Transient
module:
-
Loading/unloading systems
analysis
-
Cooling water systems
modeling
-
Firewater systems surge
analysis
-
Water injection systems
studies
-
Subsea and cross country
pipelines
-
Steam hammer
Click on image to enlarge
Click on image to enlarge
PIPENET
Transient is the perfect tool for
modeling
networks:
-
Pipes –
rigorous and short, mile post data
-
Valves
– operating, surge relief, control,
non-return, swing check, regulating,
bursting
disk, inertial check
-
Pumps –
simple and turbo
-
Tanks –
simple, accumulator, surge,
receiving vessel
-
Vacuum
breakers – with or without
hysteresis
__________________ |
-
Control systems
– pressure,
flow,
differential
pressure
sensors, PID
control,
transfer
functions,
switches
-
Caissons –
partially filled
pipes
-
Specifications –
extensive range
of boundary
conditions
-
Hydraulic
transient forces
– dynamic/total,
unbalanced/complex
forces
Click on image to
enlarge
-
PIPENET
Transient
Features:
Output –
graphical,
tabular and
forces output,
snapshot,
dynamic movie,
min/max tables,
pressure
envelopes,
hydraulic grade
lines
-
Initial state –
steady state,
user-defined,
run-in time,
final steady
state
-
Cavitation
modeling –
simple
cavitation,
cavity
separation with
elevation effect
-
Time step –
fixed/variable,
software/user-defined
-
Force – time
history neutral
file output for
reading by pipe
stress analysis
and finite
element programs
PIPENET
Transient
professionally
performs dynamic
analysis with
ease and
accuracy.
Click on image to
enlarge
Up5 |
|
PIPENET
VISION
Spray/Sprinkler Module
PIPENET Spray/Sprinkler Module is excellent for
hydraulic analysis of firewater systems
in compliance
with NFPA13, NFPA15 and NFPA16 rules.
This
addresses the hydraulic analysis
requirements of virtually
all national and international
standards. Ideal for the
design of systems used in critical
applications such as
offshore platforms, FPSO’s,
petrochemical plants,
power plants, refineries, ships, and
airport hangers.
Click on
image to enlarge
Applications of
PIPENET Spray/Sprinkler
module:
PIPENET
Spray/Sprinkler
is the ideal modeling tool for:
Pipes,
nozzles, fittings, overboard dump
valves,
non-return valves, orifice plates,
equipment items.
Click on image to enlarge
PIPENET Spray/Sprinkler
Features:
-
Input –
isometric or orthogonal schematic
input,
tabular input including copy and
paste from
spreadsheets
-
Underlay – import of drawings for
use as
underlays for schematic drawings
-
Output
– easy, readable output as tables,
or
display of data and results on the
schematic
____________ |
-
Choice of
calculation
modes –
hydraulically
mostremote
nozzle, inlet
pressure/flowrate
-
Orifice plates –
diameter to be
calculated
or specified
-
Multiple pump
scenarios
-
Multiple fire
scenarios
-
Block/Break of
pipes to
simulate closed
valves
and burst pipes
-
Pumps – sizing
of pumps or
user-defined
vendor’s pump
curves
Click on image
to enlarge
-
Pipe schedules –
built-in and
user-defined
pipe schedules,
lined pipes,
multiple pipe
schedules in one
system
-
Overboard dump
and minimum flow
valves
-
User defined
libraries of
pipe schedules,
nozzles,
deluge valves
and linings
Click on image to
enlarge
PIPENET
Spray/Sprinkler
module is the fire
protection
professional’s first
choice.
Up5 |
|
PIPENET Standard
Module
PIPENET Standard
Module is ideal for analysis of
general network systems handling
liquids, gases and
steam, including piping HVAC and ducting
systems.
Applications of PIPENET Standard Module:
PIPENET Standard
Models:
Pipes, ducts, fittings, pumps, fans,
check valves, control valves, nozzles,
filters, orifice plates, fixed pressure
drops.
Click on
image to enlarge
PIPENET
Standard
Features:
-
Input – isometric or
orthogonal schematic input,
tabular input including copy
and paste from spreadsheets
-
Underlay – import of
drawings for use as
underlays for schematic
drawings
-
Output – easy, readable
output as tables, or display
of data and results on the
schematic
-
Extensive library of
fittings and user-defined
fittings, using Crane data
-
Powerful pipe sizing
capability
-
Orifice plates – diameter to
be calculated or specified
-
Multiple pump scenarios
-
Block/Break of pipes to
simulate closed valves and
burst pipes
-
Pumps – sizing of pumps or
user-defined vendor’s pump
curves
-
Pipe schedules – extensive
built-in and userdefined
pipe schedules
-
Checking for cavitation,
correction for ambient
pressure decrease with
height, calculation of
hydraulic gradients and
modeling of leaks
|
Click on image
to enlarge
-
Control valves –
pressure, flow,
differential and
set positione
-
Variable
properties and
temperatures
-
Choice of pipe
or node
elevations
PIPENET
is the solution in
design optimisation
and
setting standards in
safety.
Click on image to
enlarge
Click on image to
enlarge
Up5 |
|
|
|